Introducing the equipment used at our facility. Please use it for evaluation in research and development.

High-Power, High-Resolution Micro X-ray CT Scanner Nikon XT H320

02
Minimum Spot Size
Approx. 30 μm with 320 kV tube / approx. 3 μm with 225 kV tube
Sample Weight
Up to 100 kg

This high-power, high-resolution micro X-ray CT scanner is manufactured by Nikon. The X-ray generator supports tube voltages up to 320 kV, and the sample stage can accommodate specimens weighing up to 100 kg.

With spatial resolution comparable to existing micro-CT scanners, it enables CT imaging of large specimens and samples under experimental conditions that were previously difficult to scan.

Setting up the sample stage
Preparing the sample for imaging, from lower left to right
Setting up the experimental apparatus
Experimental apparatus after setup
Controller
Console panel
Previous slide
Next slide

Basic Specifications

X-ray Tube Type
Open-type microfocus X-ray tube
Maximum Energy
225 kV / 320 kV, 1000 mA
Maximum Output
225 W / 320 W
Minimum Spot Size
3 μm with 225 kV tube
30 μm with 320 kV tube
Detector
Flat panel detector (FPD)
Matrix Size
2048×2048 Pixel
Maximum Sample Weight
100Kg
Approximate Scannable
Sample Size
φ150 mm
* Cylindrical aluminum (density: 2.7 g/cm³)

Use Cases

Geotechnical and Geoenvironmental Engineering
Image analysis of soil deformation behavior
Image analysis of fluid behavior in soil based on residual fluid states
Earth Science and Resource Engineering
Pore structure analysis of rocks
Permeability evaluation of underground resources
Microstructural analysis of geological formations, and more
Materials Science and Engineering
Analysis of internal defects in metal materials, including voids, cracks, and inclusions
Evaluation of internal structures in powder metallurgy and sintered materials
Fiber distribution and delamination in composite materials such as CFRP, and more
Mechanical and Manufacturing Engineering
Analysis of casting defects such as blowholes and shrinkage cavities
Internal quality evaluation of additive manufacturing (AM) parts
Dimensional measurement of parts using CT metrology, and more

It can also be used in fields such as:

  • Imaging and evaluation of metal and mechanical materials
  • Non-destructive testing of fossils, archaeological remains, and related materials
  • Imaging and evaluation of bones, fiber distribution, and ceramic samples
  • Imaging and evaluation of rubber materials